GUIDE TO INSTALLATION AND OPERATION
4 | SDA-1401
Panels are available for the Densité 2RU frame, and also for the Densité 3RU
frame. The 3RU versions are identified by the number 3 in the size designator
portion of the part number, e.g.
SDA-1401-SRP is a 2RU version
SDA-1401-3SRP is a 3RU version
Panels denoted by the suffix –R incorporate a bypass protection relay, as described
in the next section.
2RU panels are available for the 1x4 configuration (single-width rear) and the 1x9
configuration (double-width rear)
3RU panels are available for the 1x7 configuration (single-width rear)
2RU panels can be mounted in the 3RU frame if required, using mounting
adapter hardware.
The SDA-1401 detects the type of rear that is installed, and configures itself
accordingly.
In all cases, the rear panel includes:
ASI IN – one input on a BNC connector
ASI OUT – the appropriate number of outputs (4, 7 or 9) on BNC connectors
2.4 Bypass Protection Relay
A bypass protection relay is mounted on the SDA-1401-SRP-R, SDA-1401-DRP-R and SDA-1401-3SRP-R
rear panels.
The 1
st
output BNC is tied to the input via the non-latching relay which receives its power from the SDA-1401
card. The relay will trip upon detection of loss of card power, either through supply failure or removal of the
card from the Densité frame.
The relay enables the following functions
Bypass the electronic circuit
Protect the output when power is lost
Protect the output when card is removed from the frame
Figure 2.2 SDA-1401 3RU