Door/Window sensorDoor/Window sensor
1. Transmitter part - Built-in antenna..
2.Control indicator LED -When
pressing the Tamper contact button, or
when the unit is transmitting a signal
to the base station, this LED will light
up. When the LED blinks weakly,
batteries have to be replaced.
3. Magnet contact - The distance
between magnet and contact may not
be more than 5mm. When mounted,
make sure the small arrows on the
magnet and transmitter base part are
lined up.
4. Screw holes for mounting the
sensor.
5. Switch for entry delays -For
setting a delay time of approximately 30 seconds.
6. Tamper contact .
7. Battery compartment (2xAAA, 1.5V).
8. Connecting for extra wired contact.
Mounting the Door/Window Sensor DS18
1.Open the casing by taking the two pieces apart. Mount the transmitter part on the frame of your door or widow.
Do not close the casing yet.
2.Mount the magnet on the moving part of your door of window. Make sure that the arrows on the transmitter part
(see the arrow) and the magnet are facing each other when the door or window is closed. Keep the distance
between the transmitter part and the magnet (when door or window is closed) as small as possible(max 5mm).
Door/Window sensors may be hidden behind drapes for a more discreet installation.Set the switch for entry
delay(5) to MIN when you have installed the sensor on a widow and on MAX when the sensor is installed on a
door. When the switch is set to MAX, you have time to open and close the door without triggering the alarm. If you
want an instant alarm (on e.g) the backdoor), set the switch to MIN. Activate the sensor by pressing the tamper
contact(6) onthe transmitter for 4 seconds. Release the button. The door/window sensor has now chosen a unique
code, which can be registered with your console.Place the sensor as high as possible: This gives the best range.
Do not place the magnet directly on a metal surface.In case of metal frame, or synthetic frames with a metal core,
place a piece of wood or plastic (min 5mm thick) between the magnet and the frame. On metal frames the space
between the sensor and magnet should be no more than 3mm when the window or door is closed
Registering a Door/Window Sensor with the Console
1.To access the menu, press either the menu upp or down button. The display now shows ENTER PIN.
2.Enter your 4-digit PIN code. The display is cleared and shows a * for each number entered.
3.When the PIN code has been entered correctly, the word INSTALL will show up on the display.
4. Press OK.
5. Open your door or window. The console will beep to confirm. The display will read ZONE 1 SET. A memory
space for a sensor is called a zone. If you have more than 1 sensor installed, it will show e.g ZONE 2 SET.ZON 3
SET --- ZON 30 SET.
You can choose in witch zone you want to install the sensor. If you want to install the sensor in zone 3, press 3 on
the number pad before executing step 5. It’s advisable to write down which zone contains which sensor.
6. Repeat step 5 for every door/window sensor you wish to register.
7. Press CLEAR to go back to the first menu item. Press CLEAR again to quit the menu. To confirm this choice,
press 1 for Yes or 2 for No. If you choose Yes, you will quit the menu.If you choose No, you go back to the first
menu item.
Adding a wired sensor to the D/W sensor
The Ds18 Door/Window sensor has a contact for a extra wired sensor. These sensors needs to be of type of type
NC (normally closed dry contacts) and there should not be any power on this contact (potential-free).
1.Open the transmitter part.
2.Remove the wired bridge from connection and connect your additional sensor.
The wired contact can have it’s dedicated zone registration on the Security Base Console. You can register the
contact using the procedure as described above.
NOTE! You can also use Door/Window contact DS10 to the alarm.